Modular energy systems and solutions for critical infrastructure.
Signed in as:
filler@godaddy.com
Modular energy systems and solutions for critical infrastructure.
Signed in as:
filler@godaddy.com

Nex1 delivers modular, natural gas-fueled power systems designed for prime, behind-the-meter operation. These solutions provide reliable, dispatchable electricity independent of the grid, enabling customers to secure uptime, control energy costs, and scale power with demand.
Built on proven high-efficiency genset platforms , Nex1 systems are engineered for islanded or grid parrallel prime power, making them ideal for high-load, mission-critical applications.
1MW to 1GW+ Power Stations
Click the configurator below to enter your project specific requirements or schedule a guided solution configuration from the home page.

The Utility Series™ delivers industrial to utility-scale power in modular power blocks engineered for minimum footprint, rapid deployment, prime operation, and grid-parallel or islanded modes.
Natural Gas/Hydrogen
Prime and Continuous Operation
4-6 MW Blocks
4MW to 180MW+ Configurations
5kV to 38kV Class Options
0.02 g/bhp NOx
US Content, EPA Certified,UL2200
Power blocks can be configured in one or more blocks of of two lean-burn natural gas gensets in a stacked configuration,and optional heat recovery for CHP applications.

The Resiliency Series™ delivers commercial to utility-scale power in modular power blocks engineered for rapid deployment, prime operation, and grid-parallel or islanded modes.
Natural Gas/Hydrogen
Prime and Continuous Operation
1 - 3MW Blocks
1MW to 180MW+ Configurations
600V to 38kV Class Options
0.02g/bhp NOx
US Content, EPA Certified, UL2200
Power blocks can be configured with one or more lean-burn natural gas gensets and optional heat recovery for CHP applications.

The Resiliency DR Series™ delivers commercial to utility-scale power in modular power blocks engineered for rapid deployment, standby and prime operation, and grid-parallel or islanded modes.
Natural Gas/Propane
Standby and Prime Operation
1MW-3.5MW Blocks
1MW to 180MW+ Configurations
600V to 38kV Class Options
0.05g/bhp NOx
US Content, EPA Certified, UL2200, NFPA 110
Power blocks can be configured with two or more rich-burn natural gas gensets.

The Resiliency DRS Series™ delivers commercial to utility-scale power in modular power blocks in a stacked configuration; engineered for rapid deployment, standby and continuous operation, and grid-parallel or islanded modes.
Natural Gas/Propane
Standby and PrimeOperation
2MW-11MW Blocks
2MW to 180MW+ Configurations
600V to 38kV Class Options
0.05g/bhp NOx
US Content, EPA Certified, UL2200, NFPA 110
Power blocks can be configured with four or more rich-burn natural gas gensets.

Utility-Grade City Gate Metering, Filtration & Control
Capacity: Configurable for project-specific flow requirements; designed to support behind-the-meter power plants from individual power blocks to multi-hundred-MW and multi-GW campus deployments when paired with TRUXX modular gas conditioning systems.
Applications:
(1) Data center campuses receiving high-pressure
utility or transmission pipeline gas
(2) Behind-the-meter power plants requiring
custody transfer and controlled gas entry
(3) Industrial parks and manufacturing hubs with
centralized gas infrastructure
(4) Private microgrids serving multiple generation
assets or tenants
(5) Energy developers / IPPs deploying phased
on-site generation projects
(6) Sites requiring integrated gas filtration,
metering, isolation, and control in addition to
downstream letdown and conditioning
Capabilities:
Value:
A standardized city gate entry platform that transforms utility gas interconnects into controlled, measured, and protected fuel infrastructure—reducing EPC complexity, improving gas system visibility, supporting custody transfer accuracy, and enabling reliable downstream conditioning for mission-critical behind-the-meter power generation.

Mission-Critical Gas Conditioning
Capacity Range: Up to ~70 MMSCFD per TRUXX unit; scalable from ~2 MW power blocks to multi-GW campuses using parallel modular units.
Applications:
(1) Hyperscale data center campuses deploying
behind-the-meter generation
(2) Gas turbine and reciprocating engine power
plants requiring stable fuel gas
(3) Microgrids and distributed generation systems
with rapid load variability
(4) Industrial energy systems supplied from
high-pressure pipeline gas
(5) Bridge-to-grid projects requiring redeployable
gas infrastructure
(6) Multi-phase power campuses needing scalable,
standardized gas conditioning
Capabilities:
Value:
Purpose-built gas conditioning infrastructure that converts high-pressure pipeline gas into stable, generator-ready fuel—accelerating time-to-power, reducing EPC risk, preventing trips and derates, and enabling scalable behind-the-meter power deployment for mission-critical sites.

Fully Manged Gas Distribution and Control
Capacity: Configurable for site-specific flow and pressure requirements; supports multiple TRUXX units, power blocks, genset yards, turbines, and phased campus expansion from 5 MW nodes to multi-GW deployments.
Applications:
(1) Hyperscale data center campuses with multiple
behind-the-meter power blocks
(2) Reciprocating engine and turbine plants requiring
balanced fuel distribution
(3) Private microgrids serving multiple facilities,
tenants, or generation assets
(4) Industrial parks and manufacturing hubs with
centralized gas supply infrastructure
(5) Phased power deployments requiring scalable
header expansion
(6) Sites requiring standardized gas routing between
TRUXX conditioning systems and downstream loads
Capabilities:
Value:
A standardized distribution backbone that routes conditioned gas from TRUXX units to multiple power assets—reducing field construction complexity, improving fuel delivery coordination, and enabling scalable, repeatable gas infrastructure for mission-critical behind-the-meter power campuses.